7079 |
— |
Borehole |
Puntland Ministry of Energy Minerals and Water |
2022-02-19 |
Nugaal |
garowe |
Yoombays |
1.3 |
ISRC |
19/08/2019 |
Yoombays BH |
— |
8.0214834 |
49.0024209 |
511.0 |
— |
0 |
— |
rural urban |
yes |
— |
Yes |
— |
15000 |
50000 |
5000 |
35000 |
0.0 |
— |
320.0 |
pvc |
8.0 |
— |
12.0 |
20.0 |
— |
2.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Concrete/Masonry tank |
50.0 |
Galvanised Steel |
250.0 |
1500 |
3 |
2 |
yes |
15 |
90.0 |
Submersible Pump |
Lowara
|
16.0 |
290.0 |
Hybrid - Solar/Generator |
Parkins |
50.0 |
— |
12.0 |
good |
It is very good |
yes |
Colorless, odorless |
34.8 |
6.77 |
3950.0 |
1936.0 |
— |
Communal |
yes |
15/08/2020 |
3 |
2 |
yes |
0.3 |
yes |
— |
— |
— |
Agency not specified |
— |
This is new borehole with good water supply |
Fuel
Construction of new elevated tank
Training for water committees. |
— |
— |
7076 |
— |
Borehole |
Puntland Ministry of Energy Minerals and Water |
2022-02-19 |
Nugaal |
garowe |
Awr-culus |
0.8 |
CARE Somalia |
19/02/2016 |
Awr-culus BH |
— |
8.0534817 |
48.6095122 |
676.0 |
— |
0 |
— |
urban rural |
yes |
— |
Yes |
— |
10000 |
15000 |
1500 |
8000 |
0.0 |
— |
260.0 |
pvc |
8.0 |
150.0 |
8.0 |
15.0 |
— |
2.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Concrete/Masonry tank |
25.0 |
Galvanised Steel |
160.0 |
500 |
5 |
3 |
yes |
6 |
36.0 |
Submersible Pump |
Lowara |
5.5 |
180.0 |
Hybrid - Solar/Generator |
CEOlMO |
30.0 |
— |
14.4 |
fair |
Needs rehabilitation supplies |
no |
— |
30.3 |
7.15 |
4720.0 |
2350.0 |
— |
Communal |
no |
— |
— |
— |
yes |
0.3 |
yes |
— |
— |
— |
Puntland MoEMW |
19/02/2017 |
Pump repaired.
Generator repaired provide by PWDA |
Rehabilitation kiosks.
Rehabilitation for animal thoughts. |
— |
— |
7089 |
— |
Borehole |
Puntland Ministry of Energy Minerals and Water |
2022-02-19 |
Nugaal |
eyl |
Xasbahalle |
0.3 |
ICRC |
19/02/2007 |
Xasbahalle BH 2 |
— |
7.9616741 |
49.1638283 |
512.0 |
— |
1 |
— |
rural urban |
yes |
— |
Yes |
— |
1500 |
10000 |
— |
15000 |
0.0 |
— |
300.0 |
pvc |
8.0 |
— |
5.0 |
15.0 |
— |
4.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Concrete/Masonry tank |
20.0 |
Galvanised Steel |
300.0 |
150 |
1 |
2 |
yes |
3 |
24.0 |
Submersible Pump |
Lowara |
7.5 |
285.0 |
Hybrid - Solar/Generator |
Parkins |
45.0 |
— |
11.0 |
fair |
Supply is not good |
yes |
Colorless and odorless |
32.2 |
7.1 |
3570.0 |
1764.0 |
— |
Communal |
yes |
19/02/2007 |
5 |
2 |
yes |
0.1 |
yes |
— |
— |
— |
KAALO Relief and Development |
19/12/2020 |
Rehabilitation and extension of solar power |
1. Construction of new kiosks.
2. New generator.
3. Extension solar power.
4. Rehabilitation of kiosks.
6. New one latrine.
7. Reconstruction of generator room.
8. Rehabilitation and Installation of new pump and pipes. |
— |
— |
7284 |
— |
Borehole |
Puntland Ministry of Energy Minerals and Water |
2022-02-19 |
Nugaal |
eyl |
Xasbahalle |
— |
Chinese Government |
19/02/1986 |
Xasbahalle BH |
— |
7.9635816 |
49.1609604 |
512.0 |
— |
1 |
— |
rural urban |
yes |
— |
Yes |
— |
2500 |
500 |
— |
1500 |
0.0 |
— |
230.0 |
pvc |
8.0 |
— |
6.0 |
15.0 |
— |
2.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Concrete/Masonry tank |
60.0 |
Galvanised Steel |
200.0 |
500 |
1 |
2 |
no |
— |
— |
Submersible Pump |
Lowara |
7.5 |
220.0 |
Hybrid - Solar/Generator |
Parkins |
30.0 |
— |
5.5 |
fair |
The consition of this supply system is very poor |
yes |
Colorless and odorless |
30.3 |
6.85 |
3880.0 |
1929.0 |
— |
Communal |
no |
— |
— |
— |
yes |
0.1 |
yes |
— |
— |
— |
Puntland MoEMW |
20/01/2021 |
Pipeline repaired |
1. Needs rehabilitation of koiks.
2. Construction of new new kiosks.
3. Construction of animal thoughts.
4. Fuel. |
— |
— |
7074 |
— |
Borehole |
Puntland Ministry of Energy Minerals and Water |
2022-02-19 |
Bari |
qardho |
Dangorayo |
1.0 |
TASS |
18/01/2007 |
Dangorayo borehole |
— |
8.7252347 |
49.3311253 |
585.0 |
— |
1 |
— |
rural urban |
yes |
— |
No |
12/2/2022 the day stopped functioning.
Main raising pipes requires changing. |
9600 |
2000 |
0 |
5000 |
1.0 |
— |
412.0 |
pvc |
8.0 |
210.0 |
12.0 |
9.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Concrete/Masonry tank |
100.0 |
Galvanised Steel |
1000.0 |
1600 |
0 |
2 |
yes |
5 |
9.0 |
Submersible Pump |
Lawara |
— |
250.0 |
Hybrid - Solar/Generator |
Perkins |
60.0 |
300-72M |
27.0 |
good |
Pump conditionis is good,
Condition of the pipelines are good. elevated water tank is intact. |
no |
— |
— |
— |
— |
— |
— |
Communal |
yes |
01/01/2022 |
10 |
0 |
yes |
0.0 |
yes |
— |
— |
— |
NRC |
28/05/2021 |
Replacement of main raising pipe. |
Replacement of the main raising pipes. |
— |
— |
2164 |
BHWGHA061 |
Borehole |
Somaliland_MoWRD |
2019-12-22 |
Woqooyi Galbeed |
Hargeisa |
Geed deeblah |
3.0 |
Private |
22-12-19 |
Abdi Salam turkey |
— |
9.7717 |
44.015 |
1088.0 |
4.9 |
2 |
1577000841800.jpg |
Urban |
Yes |
— |
Yes |
— |
— |
— |
— |
— |
— |
— |
90.0 |
PVC |
8.0 |
70.0 |
6.8 |
9.0 |
3.0 |
1.3 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Concrete/Masonry tank |
60.0 |
PVC |
1000.0 |
0 |
0 |
0 |
No |
— |
— |
Submersible Pump |
Lowara UK |
2.0 |
65.0 |
Solar |
— |
— |
Phot VA |
45.0 |
Good |
— |
Yes |
— |
25.1 |
7.94 |
1170.0 |
590.0 |
— |
Private/Individual |
— |
— |
— |
— |
No |
— |
No |
— |
— |
— |
— |
— |
— |
— |
— |
Strategic Water Sources Survey – WSS_NATl |
2168 |
BHWGHA065 |
Borehole |
Somaliland_MoWRD |
2019-12-22 |
Woqooyi Galbeed |
Hargeisa |
Geeddeebleh |
3.0 |
Private |
17-07-84 |
Hasan askar borehole 1 |
— |
9.7654 |
44.0167 |
1090.0 |
4.9 |
2 |
1576996819647.jpg |
Urban |
No |
0 |
Abandoned |
The borehole stopped fan raising |
— |
— |
— |
— |
— |
— |
32.0 |
PVC |
8.0 |
15.0 |
0.0 |
0.0 |
— |
0.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Other |
0.0 |
Other |
0.0 |
0 |
0 |
0 |
No |
— |
— |
No Pump |
— |
— |
— |
— |
— |
— |
— |
— |
Poor |
Condition of supply is very boor becouse the bore hole is abanded |
No |
— |
— |
— |
— |
— |
— |
Private/Individual |
— |
— |
— |
— |
No |
— |
No |
— |
— |
— |
— |
— |
— |
Drilling borehole and regulations the borehole |
— |
Strategic Water Sources Survey – WSS_NATl |
2170 |
BHWGHA067 |
Borehole |
Somaliland_MoWRD |
2019-12-22 |
Woqooyi Galbeed |
Hargeisa |
Geed deeblah |
3.0 |
Private |
22-12-19 |
X. Abokor borehole 1 |
— |
9.7678 |
44.0176 |
1091.0 |
4.9 |
2 |
1577000105599.jpg |
Urban |
No |
— |
Abandoned |
— |
— |
— |
— |
— |
— |
— |
— |
GI |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Other |
— |
Other |
— |
— |
— |
— |
No |
— |
— |
No Pump |
— |
— |
— |
— |
— |
— |
— |
— |
Poor |
— |
No |
— |
— |
— |
— |
— |
— |
Private/Individual |
— |
— |
— |
— |
No |
— |
No |
— |
— |
— |
— |
— |
— |
— |
— |
Strategic Water Sources Survey – WSS_NATl |
2151 |
BHWGHA050 |
Borehole |
Somaliland_MoWRD |
2019-12-22 |
Woqooyi Galbeed |
Hargeisa |
Geed deeble |
3.0 |
Private |
22-04-18 |
Sacdudiin borehole 2 |
— |
9.7826 |
44.0058 |
1073.0 |
4.9 |
2 |
1577003389421.jpg |
Urban |
Yes |
— |
Yes |
— |
— |
— |
— |
— |
— |
— |
80.0 |
GI |
8.0 |
40.0 |
10.0 |
10.0 |
— |
0.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Concrete/Masonry tank |
100.0 |
Stainless Steel |
700.0 |
0 |
0 |
0 |
No |
— |
— |
Submersible Pump |
Lowara UK |
3.0 |
70.0 |
Solar |
— |
— |
Photo valtus |
1.44 |
Good |
The condition of supply system is very good |
Yes |
— |
29.5 |
7.23 |
10.0 |
500.0 |
— |
Private/Individual |
— |
— |
— |
— |
No |
— |
No |
— |
— |
— |
Jambaq (Owner ) |
— |
— |
— |
— |
Strategic Water Sources Survey – WSS_NATl |
2119 |
BHWGHA018 |
Borehole |
Somaliland_MoWRD |
2019-12-22 |
Woqooyi Galbeed |
Hargeisa |
Geeddeebleh |
2.0 |
Chinese Government |
01-06-70 |
Geeddeebleh bore2 |
— |
9.7741 |
43.9648 |
1076.0 |
4.9 |
14 |
1577005715994.jpg |
Urban |
No |
7 |
Abandoned |
Is reserve |
— |
— |
— |
— |
— |
— |
108.0 |
Other |
8.0 |
21.0 |
0.0 |
0.0 |
— |
0.0 |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
— |
Other |
0.0 |
Other |
30000.0 |
0 |
0 |
0 |
No |
— |
— |
No Pump |
— |
— |
— |
— |
— |
— |
— |
— |
Poor |
The condition of supply system is very boor becouse the bore hole is abandan |
No |
— |
— |
— |
— |
— |
— |
Other |
— |
— |
— |
— |
No |
— |
No |
— |
— |
— |
— |
— |
— |
— |
— |
Strategic Water Sources Survey – WSS_NATl |